IN SITU MEASUREMENTS OF THE AXIAL EXPANSION OF PALLADIUM MICRODISKS DURING HYDROGEN EXPOSURE USING DIFFRACTION PHASE MICROSCOPY

Chris Edwards,1,2,4 Steven J. McKeown,1,4 Jerry Zhou,1,3 Gabriel Popescu,2 and Lynford L. Goddard1*
OPTICAL MATERIALS EXPRESS 2559, Vol. 4, No. 12 2014

 

We measured the height of Pd microdisks during H2 exposure using epi-illumination diffraction phase microscopy, a quantitative phase imaging technique for capturing nanoscale dynamics in situ. From these microdisk height measurements, we extracted the axial expansion coefficient as a function of H2 concentration as well as image sequences that show the instantaneous rate of axial expansion in a spatially and temporally resolved manner. Quantifying these two parameters is important in modeling Pd-based H2 sensors. For H2 concentrations below 0.5%, i.e. an order of magnitude below the lower explosive limit, the axial expansion coefficient followed the Freundlich distribution: Δh(c) = 1.28 c0.51 where Δh is the percentage change in height of the Pd microdisk and c is the percent concentration of H2 in N2. The fit agrees well with the anticipated square root dependence for diatomic gas.

Scroll to top
Phi Optics
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.